Wire Size Setting
The wire size is set by turning the yellow know (1) Check wire size indicator (11) for reference.
Remarks: The wire size indicator (11) is adjusted for wire with standard PVC insulation With non standard insulation, or if wire size is not known, the suitable setting must be established on a trial / error basis.
It is recommended to start the setting from a larger size and then work down to the final setting.
If insulation is cut too deep of not deep enough adjust the setting accordingly.
Strip Length setting
The stripping length is set by turning the blue know (6) Check stripping length indicator (12) for reference.
Insulation removal setting
For complete stripping push selector knob (2) and turn to symbol 
For partial removal of insulation push selector knob (2) and turn to symbol
Insertion of wire
Insert wire horizontally into wire entry until it putts against stop
Touching the stop actuates the stripping operation
Remove stripped wire
Waste
The stripped insulation material is collected in the sliding box at the right side. The box has to be emptied from time to time
When the machine is extensively used it can be more practical to work without the waste box |